SOLUTIONS | ELECTRICAL
ELECTRICAL SOLUTIONS
AUTO & MANUAL SYNCHRONIZING PANELS
- Indoor & outdoor applications, up to IP65 with ambient temperature 55 deg C.
- Main busbar up to 7000 A
- Rated voltage up to 690 V (Low Voltage) & 25KV (Medium Voltage)
- Wide range of controllers offer using (DEIF, Terberg, Deepsea, Gensys, Comap), reliability and flexibility.
- Gen-set controller for single or multiple generating sets operating in standby or parallel modes
- Many communication options – easy remote supervising and servicing
- Gen-set performance log for easy problem tracing
- Automatic synchronizing and power control (via speed governor or ECU)
- AMF function, Baseload, Import / Export, Peak shaving, Voltage and PF control (AVR)
- Generator measurement, Mains measurement
- Inputs and outputs configurable for various customer needs redundancy
- Event-based historical record (up to 500 records) with customer-selectable list of stored values; RTC; statistic values
- Integrated PLC programmable functions
- Integrated fixed and configurable protections
- Selectable measurement ranges for AC voltages and currents.
AUTO & MANUAL TRANSFER SWITCHES
- The source changeovers ensure, in an optimised volume, the energy availability in critical electrical installations:
- Maximum continuity of service
- Optimized energy management
- Simplicity of the system based on pre-tested components
- Switching of a main energy source to a replacement source, performed either manually or automatically, in LV electrical installations and in particular in:
- Buildings: hospitals, banks, insurance firms, military installations, commercial buildings
- Industry: continuous production line (chemicals, glass), mining, ship engine rooms
- Infrastructures: airports, ports, railway installations, highway, water treatment, telecommunication
- As per IEC 60439-1, IEC 60947-3 Standards
- As per UL 1008 & CSA C22.2 NO. 178.1-14 Standards
- Rated Insulation Voltage: 1000VAC
- Rated Operational Voltage: 690VAC
- Ratings: up to 6300A
- Degree of Protection: up to 54
- ATS with single & Dual Bypass system
- ATS with Mechanical & Electrical interlocking
MOTOR CONTROL CENTER (MCC)
-
Type tested as per IEC 61439-1 and -2
-
Local/ remote real-time access, and automatic restarting
-
Motor control up to 250 kW
-
Rated voltage up to 690 V
-
Thermal monitoring
-
Type 2 coordination
-
Protection degrees up to IP54
-
Withdrawable, disconnectable, and fixed functional units
-
Rear/ front access, top/ bottom connection, double-front access
-
Compliant with seismic 2G resistant versions
-
Segregation Form: up to 4b
MEDIUM VOLTAGE (MV) IEC AIR INSULATED SWITCH GEAR
- MV switchgear for primary distribution up to 24 kV suitable for indoor installations.
- Primary distribution up to 24 kV, 4 000 A, 63 kA.
- Distribute electric power in a variety of demanding applications such as on off-shore platforms, in container or cruise ships, in mines as well as in utility substations, power plants or chemical plants.
- Panels are available as a single busbar, double busbar, back-to-back or double level solution.
- Product range of the Unigear MV Solution.
- Rated voltage up to 24 kV; rated feeder current up to 4 000 A; rated short time current up to 63 kA / 1 s (50 kA / 3 s).
- Key benefits of the Unigear MV Solution.
- 24 kV, 4 000 A, 63 kA
- Manufactured and supported on six continents
- Approved for use in special applications such as marine, seismic and nuclear
- Variety of demanding applications
- Key features
- Standards: IEC, CSA, GOST, GB/DL
- Design: LSC-2B, PM
- Internal arc class: A FLR
- Highly customized versions available
- Switchgear can be back to wall installed
- Available in Digital version
MAIN DISTRIBUTION BOARDS (MDB)
- Safety of persons, as well as reliability and continuity of service of the electrical installation
- Power feeder up to 6300 A
- Main busbar up to 7000 A
- Rated voltage up to 690 V
- Type tested system as per IEC 61439-1 and -2 up to 5000A
- Isolated live parts up to IPxxD up to form 4b Type 6
- Protection degrees up to IP54
- Rear/ front access, top/ bottom connection, double-front access