SOLUTIONS | ELECTRICAL

ELECTRICAL SOLUTIONS

AUTO & MANUAL SYNCHRONIZING PANELS

  • Indoor & outdoor applications, up to IP65 with ambient temperature 55 deg C.
  • Main busbar up to 7000 A
  • Rated voltage up to 690 V (Low Voltage) & 25KV (Medium Voltage)
  • Wide range of controllers offer using (DEIF, Terberg, Deepsea, Gensys, Comap), reliability and flexibility.
  • Gen-set controller for single or multiple generating sets operating in standby or parallel modes
  • Many communication options – easy remote supervising and servicing
  • Gen-set performance log for easy problem tracing
  • Automatic synchronizing and power control (via speed governor or ECU)
  • AMF function, Baseload, Import / Export, Peak shaving, Voltage and PF control (AVR)
  • Generator measurement, Mains measurement
  • Inputs and outputs configurable for various customer needs redundancy
  • Event-based historical record (up to 500 records) with customer-selectable list of stored values; RTC; statistic values
  • Integrated PLC programmable functions
  • Integrated fixed and configurable protections
  • Selectable measurement ranges for AC voltages and currents.

AUTO & MANUAL TRANSFER SWITCHES

  • The source changeovers ensure, in an optimised volume, the energy availability in critical electrical installations:
  • Maximum continuity of service
  • Optimized energy management
  • Simplicity of the system based on pre-tested components
  • Switching of a main energy source to a replacement source, performed either manually or automatically, in LV electrical installations and in particular in:
  • Buildings: hospitals, banks, insurance firms, military installations, commercial buildings
  • Industry: continuous production line (chemicals, glass), mining, ship engine rooms
  • Infrastructures: airports, ports, railway installations, highway, water treatment, telecommunication
  • As per IEC 60439-1, IEC 60947-3 Standards
  • As per UL 1008 & CSA C22.2 NO. 178.1-14 Standards
  • Rated Insulation Voltage: 1000VAC
  • Rated Operational Voltage: 690VAC
  • Ratings: up to 6300A
  • Degree of Protection: up to 54
  • ATS with single & Dual Bypass system
  • ATS with Mechanical & Electrical interlocking

MOTOR CONTROL CENTER (MCC)

  • Type tested as per IEC 61439-1 and -2

  • Local/ remote real-time access, and automatic restarting

  • Motor control up to 250 kW

  • Rated voltage up to 690 V

  • Thermal monitoring

  • Type 2 coordination

  • Protection degrees up to IP54

  • Withdrawable, disconnectable, and fixed functional units

  • Rear/ front access, top/ bottom connection, double-front access

  • Compliant with seismic 2G resistant versions

  • Segregation Form: up to 4b

MEDIUM VOLTAGE (MV) IEC AIR INSULATED SWITCH GEAR

  • MV switchgear for primary distribution up to 24 kV suitable for indoor installations.
  • Primary distribution up to 24 kV, 4 000 A, 63 kA.
  • Distribute electric power in a variety of demanding applications such as on off-shore platforms, in container or cruise ships, in mines as well as in utility substations, power plants or chemical plants.
  • Panels are available as a single busbar, double busbar, back-to-back or double level solution.
  • Product range of the Unigear MV Solution.
  • Rated voltage up to 24 kV; rated feeder current up to 4 000 A; rated short time current up to 63 kA / 1 s (50 kA / 3 s).
  • Key benefits of the Unigear MV Solution.
  • 24 kV, 4 000 A, 63 kA
  • Manufactured and supported on six continents
  • Approved for use in special applications such as marine, seismic and nuclear
  • Variety of demanding applications
  • Key features
  • Standards: IEC, CSA, GOST, GB/DL
  • Design: LSC-2B, PM
  • Internal arc class: A FLR
  • Highly customized versions available
  • Switchgear can be back to wall installed
  • Available in Digital version

MAIN DISTRIBUTION BOARDS (MDB)

  • Safety of persons, as well as reliability and continuity of service of the electrical installation
  • Power feeder up to 6300 A
  • Main busbar up to 7000 A
  • Rated voltage up to 690 V
  • Type tested system as per IEC 61439-1 and -2 up to 5000A
  • Isolated live parts up to IPxxD up to form 4b Type 6
  • Protection degrees up to IP54
  • Rear/ front access, top/ bottom connection, double-front access